Waferpedia

YES

310TA

The YES 310TA is a vacuum cure and HMDS vapor prime oven for enhancing photoresist adhesion. The YES 310TA operates at 150°C with a 300-second HMDS vapor exposure. The YES 310TA treats wafers up to 6 inches in diameter.[1][2]

310TA — colorado.edu
Fig. 01310TAcolorado.edu[2]

Wafer size

up to 6-inch wafers

Vacuum

Vacuum cure & HMDS vapor prime oven[1]

Optics

300 s[1]

What it is

The YES 310TA is a vacuum cure and HMDS vapor prime oven used in photolithography-related thermal processing.[1][4]

How it works

The YES 310TA performs HMDS vapor priming in vacuum-cure and vapor-prime operation.[1][3]

The YES 310TA uses vapor-phase HMDS at one hundred fifty degrees Celsius with an exposure time of three hundred seconds and a total process time of about fifteen minutes.[1]

Where it fits in the process flow

The YES 310TA sits before photoresist spin coating as a priming step that improves adhesion.[1][3]

The YES 310TA is used for batch processing of wafers in cassettes and is followed by cooling before spin coating.[1]

Applications

The YES 310TA primes silicon, silicon dioxide, and silicon nitride with silane molecules to improve adhesion of polymers such as photoresists.[1]

  • Batch priming of Si, native or film SiO2, and Si3N4
  • Enhancing adhesion of polymers such as photoresists
  • HMDS treatment before spin coating

What do the numbers mean?

Vacuum & pumping2

Description
Vacuum cure & HMDS vapor prime oven[1]
Accurate?
Equipment type
Vacuum cure & HMDS vapor prime oven[1]
Accurate?

Wafer handling8

Carrier capacity
25 slots for 4-inch or 6-inch wafers per cassette[1]
Accurate?
Wafer compatibility
up to 6-inch wafers[1]
Accurate?
Wafer capacity
25 slots for 4″ or 6″ wafers[1]
Accurate?
Maximum wafer size
up to 6-inch[2]
Accurate?
Wafer size capacity
up to 6-inch[2]
Accurate?
Cassette capacity
25 slots for 4" or 6" wafers[1]
Accurate?
Cassette capacity
25 slots for 4-inch or 6-inch wafers per cassette[1]
Accurate?
Wafer size
up to 6-inch wafers[2]
Accurate?

Optics & imaging2

Exposure time
300 s[1]
Accurate?
HMDS exposure time
300 seconds[1]
Accurate?

Configuration & options11

Model
310TA[2]
Accurate?
Equipment type
HMDS Vapor Prime Oven[2]2 sources
Accurate?
Priming agent
HMDS in vapor phase[1]
Accurate?
Process temperature
150 °C[1]
Accurate?
Total process time including purges
~15 min[1]
Accurate?
Process type
HMDS vapor priming[1]
Accurate?
Temperature
150 °C[1]
Accurate?
Total process time
~15 min[1]
Accurate?
Priming agent
Hexamethyldisilazane (HMDS)[1]
Accurate?
Total process time
~15 minutes[1]
Accurate?
Model
YES 310TA[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
YES-310TA———web.archive.org[3]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • DescriptionVacuum cure & HMDS vapor prime oven[1]
  • Equipment typeVacuum cure & HMDS vapor prime oven[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What surface treatment does the YES 310TA perform?

The YES 310TA performs HMDS vapor priming.[1]

Which materials can the YES 310TA prime?

The YES 310TA can batch prime silicon, silicon dioxide, and silicon nitride.[1]

How long does one HMDS prime cycle take?

The YES 310TA uses an exposure time of three hundred seconds and a total process time of about fifteen minutes.[1]

Not publicly documented

The following facts about the 310TA are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 310TA are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 310TA are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 310TA are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 310TA is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 310TA are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (4)Every fact above is drawn from these public sources