Produced 1987–Tektronix 2205 Oscilloscope family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Tektronix 2205 is a dual-channel analog oscilloscope with a bandwidth of 20 MHz. The 2205 provides calibrated deflection factors from 5 mV/div to 5 V/div. The 2205 features an 80 x 100 mm CRT display.[1][2]

Tektronix logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Produced

1987–

Power

20 MHz (standard); 40 MHz (Option 40)[1]

What it is

The Tektronix 2205 is an analog oscilloscope.[1]

The Tektronix 2205 has two identical vertical channels and a front-panel Z-axis input.[1]

How it works

The Tektronix 2205 includes auto triggering and a trigger sensitivity of 0.3 div.[1]

Applications

The Tektronix 2205 has a bandwidth of 40 MHz.[1]

The Tektronix 2205 has a maximum sweep rate of 10 ns/div.[1]

What do the numbers mean?

Power & electrical13

Bandwidth (-3 dB)
20 MHz (standard); 40 MHz (Option 40)[1]
Accurate?
Rise time
17.5 ns (20 MHz); 8.75 ns (Option 40, 40 MHz)[1]
Accurate?
Deflection factor (vertical sensitivity)
5 mV/div to 5 V/div ±3%[1]
Accurate?
Max input voltage
400 V (DC + peak AC), 800 V pk-pk[1]
Accurate?
Line voltage range
95 V AC to 128 V AC (low), 185 V AC to 250 V AC (high)[1]
Accurate?
Line frequency
48 Hz to 440 Hz[2]2 sources
Accurate?
Trigger sensitivity (internal)
0.30 div at 5 MHz, 1.0 div at 30 MHz[1]
Accurate?
Bandwidth
20 MHz[1]
Accurate?
Option 40 bandwidth
40 MHz[1]
Accurate?
Maximum input voltage
400 V (DC + peak AC), 800 V pk-pk[1]
Accurate?
Line voltage range
95 V AC to 128 V AC; 185 V AC to 250 V AC[1]
Accurate?
Bandwidth option
40 MHz[1]
Accurate?
Power requirements
95 V AC to 128 V AC or 185 V AC to 250 V AC; 48 Hz to 440 Hz[1]
Accurate?

Control & software2

CRT display size
80 by 100 mm[2]
Accurate?
Display
8 cm × 10 cm CRT[1]
Accurate?

Dimensions & facilities4

Dimensions (H x W x D)
137 mm x 380 mm x 440 mm[1]
Accurate?
Weight (net)
6.7 kg[1]
Accurate?
Dimensions
137 mm H × 380 mm W × 440 mm D[1]
Accurate?
Weight
6.7 kg net[1]
Accurate?

Configuration & options17

Number of channels
Dual-channel[2]
Accurate?
Max sweep speed
0.1 µs/div (X10 MAG to 10 ns/div)[1]
Accurate?
Input impedance
1 MΩ, 25 pF[1]
Accurate?
Power consumption
40 W (60 VA)[1]
Accurate?
Operating temperature
0 to +40 °C[1]
Accurate?
Vertical operating modes
CH1, CH2, CH2 INVERT, ADD, ALT, CHOP[1]
Accurate?
Warranty
1 year (3 years optional)[1]
Accurate?
Product type
Analog oscilloscope[1]
Accurate?
Channels
2 identical channels[1]
Accurate?
Auto triggering
40 peak-to-peak[1]
Accurate?
Trigger sensitivity
0.3 div[1]
Accurate?
Z-axis input
Front-panel[1]
Accurate?
Maximum sweep rate
10 ns/div[1]
Accurate?
Input resistance
1 megohm[1]
Accurate?
Input capacitance
25 pF[1]
Accurate?
Type
Analog oscilloscope[1]
Accurate?
Maximum power consumption
40 W (60 VA)[1]
Accurate?

Vintage & configurations

  1. 1987Production start[2]

    Operator's manual first printing October 1987 indicates introduction.

Documented models & variants

DesignationGenerationVintageChangesSource
Option 40——40 MHz bandwidth, 8.75 ns rise time, 6 kV CRT nominal voltage (vs 1.8 kV), higher trigger sensitivity (150 mV at 45 MHz external).tek.com[1]
2205 Option 40——40 MHz bandwidth; 6 kV nominal CRT voltage; 35 MHz bandwidth and 10 ns rise time at 0 to 40 °C are stated for this option.tek.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Bandwidth (-3 dB)20 MHz (standard); 40 MHz (Option 40)[1]
  • Rise time17.5 ns (20 MHz); 8.75 ns (Option 40, 40 MHz)[1]
  • Deflection factor (vertical sensitivity)5 mV/div to 5 V/div ±3%[1]
  • Max input voltage400 V (DC + peak AC), 800 V pk-pk[1]
  • Line voltage range95 V AC to 128 V AC (low), 185 V AC to 250 V AC (high)[1]
  • Line frequency48 Hz to 440 Hz[2]
  • Trigger sensitivity (internal)0.30 div at 5 MHz, 1.0 div at 30 MHz[1]
  • Bandwidth20 MHz[1]
  • Option 40 bandwidth40 MHz[1]
  • Maximum input voltage400 V (DC + peak AC), 800 V pk-pk[1]
  • Line voltage range95 V AC to 128 V AC; 185 V AC to 250 V AC[1]
  • Bandwidth option40 MHz[1]
  • Power requirements95 V AC to 128 V AC or 185 V AC to 250 V AC; 48 Hz to 440 Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the bandwidth of the Tektronix 2205?

The standard vertical system bandwidth is 20 MHz (-3 dB). An optional 40 MHz bandwidth is available.[1]

How many channels does the 2205 have?

The 2205 has two identical input channels.[1]

What is the maximum sweep rate of the 2205?

The maximum sweep rate is 10 ns per division.[1]

Does the 2205 have a Z-axis input?

Yes, the 2205 has a front-panel Z-axis input for external intensity modulation.[1]

What type of triggering does the 2205 support?

The 2205 supports peak-to-peak auto triggering.[1]

What is the trigger sensitivity of the 2205?

The trigger sensitivity is 0.3 divisions.[1]

Not publicly documented

The following facts about the 2205 Oscilloscope are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the 2205 Oscilloscope are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 2205 Oscilloscope are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 2205 Oscilloscope is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 2205 Oscilloscope are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the 2205 Oscilloscope are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]tek.com — tek.comtek.com
  2. [2]manualslib.com — manualslib.commanualslib.com
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →