The Perkin Elmer QSight 420 Mass is a precision-optics-category mass spectrometry instrument. The QSight 420 LC/MS/MS system is a triple quadrupole instrument.[1][2]

How it works

The QSight 420 LC/MS/MS system uses a quadrupole mass analyzer. The instrument uses dual independent probes with electrospray ionization and atmospheric pressure chemical ionization. The instrument operates in positive and negative ionization modes.[2]

The QSight 420 LC/MS/MS system supports full scan, multiple reaction mode, selected ion monitoring, product ion scan, and neutral gain or loss scan acquisition modes.[2]

Where it fits in the process flow

The QSight 420 LC/MS/MS system includes a QSight LX-50 Binary Pump, a QSight LX-50 Autosampler, a QSight LX-50 Oven, and a Flexar PDA Plus Detector.[2]

Applications

The QSight 420 LC/MS/MS system is used for trace-level quantification of target compounds. The instrument is applied in agriculture and food analysis, environmental analysis, forensic and toxicology analysis, industrial analysis, and pharmaceutical analysis.[2]

The instrument supports an MRM library of more than eight hundred compounds. The library includes pesticides and environmental contaminants including per- and polyfluoroalkyl substances such as PFOA and PFOS.[2]

What do the numbers mean?

Configuration & options5

Mass Analyzer
Quadrupole mass analyzer[2]
Accurate?
Ion Source
Dual Source with ESI and APCI Independent Probes[2]
Accurate?
Ion Polarity
Positive and Negative[2]
Accurate?
Mass Range
10 to 1000 Da[2]
Accurate?
Data Acquisition Modes
Full Scan, MRM, SIM, Product Ion Scan, Neutral gain/loss scan[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of mass analyzer does the QSight 420 LC/MS/MS system use?

The QSight 420 LC/MS/MS system uses a quadrupole mass analyzer.[2]

Which ionization methods are used on the QSight 420 LC/MS/MS system?

The QSight 420 LC/MS/MS system uses electrospray ionization and atmospheric pressure chemical ionization with independent probes.[2]

Which ionization polarities does the QSight 420 LC/MS/MS system support?

The QSight 420 LC/MS/MS system supports positive and negative ionization modes.[2]

What acquisition modes are supported by the QSight 420 LC/MS/MS system?

The QSight 420 LC/MS/MS system supports full scan, multiple reaction mode, selected ion monitoring, product ion scan, and neutral gain or loss scan acquisition modes.[2]

Not publicly documented

The following facts about the QSight 420 Mass are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the QSight 420 Mass are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the QSight 420 Mass are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the QSight 420 Mass are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the QSight 420 Mass are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the QSight 420 Mass is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]sssc.usask.ca — sssc.usask.casssc.usask.ca
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools

View all →