Neslab
The Neslab Thermoflex 10000 is a recirculating chiller from Thermo Fisher Scientific (formerly Neslab). The Thermoflex 10000 provides a cooling capacity of 10,000 watts at 20°C. The Thermoflex 10000 operates over a temperature range of +5°C to +40°C.[1][2][3]
Recirculating chillers operate by pumping a coolant fluid through a closed-loop system to a heat-generating load, then returning the warmed fluid to the chiller for cooling. The ThermoFlex 10000 uses a refrigeration system, which can be either air-cooled or water-cooled, to remove heat from the fluid. A microprocessor-based controller regulates the fluid temperature and provides alarm functions.[2]
Power requirements vary by configuration. One configuration requires 208 volts, three-phase, 60 Hz. Another configuration requires 460 VAC, 16.0 amps, 60 Hz. The chiller is available with single-phase or three-phase power options.[1][2][3]
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| ThermoFlex 7500 | — | — | Listed in a comparison table alongside the 10000 model with 5,000 W cooling capacity and 10 GPM at 20°C / 32 PSI. | trilliumus.com[3] |
| ThermoFlex 15000 | — | — | Listed in a comparison table alongside the 10000 model with 15,000 W cooling capacity and 20 GPM at 20°C / 60 PSI. | trilliumus.com[3] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The cooling capacity is 10,000 watts (34,100 BTU/hr) at 20°C.[1][2][3]
The Thermoflex 10000 is available with power supply options of 200-230V single-phase or three-phase.[3]
The chiller uses either an air-cooled or water-cooled refrigeration system.[2][3]
The Thermoflex 10000 can be equipped with different pump options. A P3 pump provides 10 GPM at 32 PSI at 20°C. A P5 pump provides 20 GPM at 60 PSI at 20°C.[3]
The following facts about the Thermoflex 10000 Chiller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Thermoflex 10000 Chiller are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the Thermoflex 10000 Chiller are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the Thermoflex 10000 Chiller are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the Thermoflex 10000 Chiller is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the Thermoflex 10000 Chiller are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Oct 2, 2026.
The ABM-407B-2-S-CE-S293 is a robot.