Waferpedia

Lam Research

2080 TCU Chiller

Lam Research 2080 TCU Chiller family
Research Quality: 20% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

Lam Research logo
Fig. — Manufacturer logo, not a photo of this toolWikimedia Commons (see file page for license)

Power

(2) 1A, 250V SLO BLO[1]

Vacuum

<75 dBA[1]

Optics

±0.1 °C[1]

What is it?

The Lam Research 2080 TCU is a dual-channel temperature control unit (chiller) for heating and cooling of upper and lower electrodes in Lam systems.

What do the numbers mean?

Power & electrical3

Power requirements
3-phase 208/230VAC at 50-60 Hz, 30 A with 10 kA Icu[1]
Accurate?
Fuses (EMO circuit)
(2) 1A, 250V SLO BLO[1]
Accurate?
Fuses (power supply)
(1) 0.75A, 250V SLO BLO[1]
Accurate?

Vacuum & pumping1

Sound pressure level
<75 dBA[1]
Accurate?

Optics & imaging1

Setpoint resolution
±0.1 °C[1]
Accurate?

Dimensions & facilities5

Height
55.25 in (140.34 cm)[1]
Accurate?
Width
23.75 in (60.33 cm)[1]
Accurate?
Depth
37.75 in (95.89 cm)[1]
Accurate?
Weight (empty reservoirs)
616 lbs (279.42 kg)[1]
Accurate?
Weight (full reservoirs)
690 lbs (312.98 kg)[1]
Accurate?

Configuration & options16

Description
Dual Channel Chiller[1]
Accurate?
Manufacturer
Lam Research[1]
Accurate?
Model
2080 TCU[1]
Accurate?
Upper channel temperature range
-15 to +80 °C[1]
Accurate?
Lower channel temperature range
-20 to +80 °C[1]
Accurate?
Temperature regulation
±1 °C (±0.3 °C typical) at rated static load[1]
Accurate?
Cooling power (lower channel at -20°C)
1000 W (3415 BTU/hr)[1]
Accurate?
Cooling power (upper channel at -15°C)
750 W (2561 BTU/hr)[1]
Accurate?
Heating power (upper/lower channel)
1600 W (5464 BTU/hr)[1]
Accurate?
Reservoir capacity (per reservoir)
4.23 gallons (16 liters)[1]
Accurate?
Ambient operating temperature
+10 to +40 °C[1]
Accurate?
Coolant composition
50/50 mixture of DI water and ethylene glycol (specific gravity 1.065 ±0.005)[1]
Accurate?
Refrigerant type
R404A[1]
Accurate?
CE mark
Yes[1]
Accurate?
Lam part number
851-110195-020D[1]
Accurate?
Country of origin
USA[1]
Accurate?

Vintage & configurations

  1. 1998-01-05Vintage date[1]

    Facilities vintage date stated as 01.05.1998

Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power requirements3-phase 208/230VAC at 50-60 Hz, 30 A with 10 kA Icu[1]
  • Fuses (EMO circuit)(2) 1A, 250V SLO BLO[1]
  • Fuses (power supply)(1) 0.75A, 250V SLO BLO[1]
  • Sound pressure level<75 dBA[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the operating temperature ranges for the upper and lower channels?

Upper channel: -15 to +80 °C. Lower channel: -20 to +80 °C.[1]

What is the temperature regulation accuracy?

±1 °C (±0.3 °C typical) at rated static load.[1]

What coolant is recommended?

A 50/50 mixture by volume of deionized water and ethylene glycol.[1]

What are the power requirements?

Three-phase 208/230 VAC at 50-60 Hz, 30 A with 10 kA Icu.[1]

How many cooling circuits does each channel have?

Each channel contains three separate cooling circuits: primary, secondary, and tertiary.[1]

Not publicly documented

The following facts about the 2080 TCU Chiller are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented variants, configuration options, or revision breakpoints of the 2080 TCU Chiller are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the 2080 TCU Chiller are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 2080 TCU Chiller are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 2080 TCU Chiller is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 2080 TCU Chiller are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]fabsurplus.com — fabsurplus.comfabsurplus.com
  2. [2]Equipment inventory listing
Was this page accurate?

Last updated Sep 26, 2026.

Compare with similar tools