The ESPEC BTX-475 is a benchtop temperature and humidity chamber with a temperature range of -70 to 180°C and a humidity range of 10% to 95% RH. The BTX-475 provides a 4-cubic-foot (110-liter) interior workspace for environmental testing. The BTX-475 has been employed in interferometric setups for measuring thermal expansion and refractive index of optical materials.[1][2]

ESPECBTX-475
No photo available yet

What it is

The ESPEC BTX-475 is a benchtop environmental chamber for temperature and humidity testing. The model is part of ESPEC's Criterion Benchtop line.[1][5]

The BTX-475 has an interior volume of 4 cu. ft. or 110 liters. The chamber is specified with interior dimensions of 19.6 inches by 15 inches by 23.6 inches and exterior dimensions of 30.25 inches by 33.5 inches by 46 inches.[1][5]

How it works

The BTX-475 uses a touch-screen controller with Ethernet, and the standard controller is a Watlow F4T. The chamber supports saved profiles with ramp, soak, jump, auto-start, and end steps, and it includes relay outputs for external device control and specimen power interlock safety.[1][5]

What do the numbers mean?

Power & electrical1

Power Requirement
208/230 V, 1ph, 60 Hz, 20 service amps (NEMA 6-20 plug)[1]
Accurate?

Performance2

Temperature Gradient (Uniformity)
±1.5 °C (below 100 °C, empty)[1]
Accurate?
Humidity Gradient (Uniformity)
±5% (empty)[1]
Accurate?

Control & software2

Temperature Fluctuation
±0.5 °C (at control sensor)[1]
Accurate?
Humidity Fluctuation
±5% (at control sensor)[1]
Accurate?

Dimensions & facilities3

Interior Dimensions (W x D x H)
19.6" x 15" x 23.6" (500 x 380 x 600 mm)[1]
Accurate?
Exterior Dimensions (W x D x H)
30.25" x 33.5" x 46" (770 x 850 x 1170 mm)[1]
Accurate?
Weight
Approx. 500 lbs (227 kg)[4]
Accurate?

Configuration & options6

Documentation
Datasheet (1 document)[3]
Accurate?
Interior Volume
4 cu. ft. (110 L)[1]
Accurate?
Temperature Range
-70 to 180 °C (-94 to 354 °F)[1]
Accurate?
Humidity Range
10% - 95% RH[1]
Accurate?
Average Heating Rate
2.75 °C/min (empty, per IEC 60068 3-5, at supply sensor)[1]
Accurate?
Average Cooling Rate
2.5 °C/min (empty, per IEC 60068 3-5, at supply sensor)[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power Requirement208/230 V, 1ph, 60 Hz, 20 service amps (NEMA 6-20 plug)[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of chamber is the BTX-475?

The BTX-475 is a benchtop humidity chamber.[1][6][4]

What is the chamber volume?

The BTX-475 has an interior volume of 4 cubic feet, or 110 liters.[1][5]

What controller is standard on the BTX-475?

The BTX-475 uses a Watlow F4T touch-screen controller with Ethernet as standard.[1][5][4]

Not publicly documented

The following facts about the BTX-475 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the BTX-475 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the BTX-475 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the BTX-475 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the BTX-475 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the BTX-475 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (6)Every fact above is drawn from these public sources
  1. [1]espec.com — espec.comespec.com
  2. [2]https://ntrs.nasa.gov/api/citations/20170006479/downloads/20170006479.pdf — ntrs.nasa.govntrs.nasa.gov
  3. [3]metrologymanuals.com — metrologymanuals.commetrologymanuals.com
  4. [4]frankbacon.com — frankbacon.comfrankbacon.com
  5. [5]BTX-475 | Products | ESPEC North America — espec.comespec.com
  6. [6]Rent Espec BTX-475 Temperature and Humidity Chamber — atecorp.comatecorp.com
Was this page accurate?

Last updated Oct 9, 2026.

Compare with similar tools

View all →