The Edwards IQDP 80 Dry is a dry vacuum pump. The Edwards IQDP 80 Dry is a four-stage, positive displacement dry pump. The Edwards IQDP 80 Dry has an indirect cooling system and a water-cooled pump motor.[1][2]

EdwardsIQDP 80 Dry
No photo available yet

Power

3 Phase, 200-460V, 50/60Hz[3]

Vacuum

96 m3/h-1[2]

How it works

The iQDP 80 pump has four stages. The timing gears and adjacent double-row angular contact ball bearings are oil lubricated, but the pumping chambers contain no lubricating fluid. The pump has an indirect cooling system and the motor is water cooled. An optional Gas Module introduces purge gas into the pump. The system can be controlled via a Pump Display Module, an Interface Module, or an iQSingle Pumpset Monitor.[2][1]

When configured with a QMB Roots booster, the booster uses a hydrokinetic fluid-coupling that automatically reduces rotor speed under high gas load and accelerates as the load decreases, allowing continuous operation over the vacuum range without bypass valves.[1]

Applications

The pump is suitable for both heavy-duty and cleanroom environments, particularly where fan cooling is unacceptable, due to its water-cooled, enclosed motor design.[1]

What do the numbers mean?

Power & electrical1

Motor
3 Phase, 200-460V, 50/60Hz[3]
Accurate?

Vacuum & pumping22

Typical Peak Pumping Speed (60Hz)
96 m3/h-1[2]
Accurate?
Pumping Speed (60Hz)
56.5 CFM[3]
Accurate?
Pumping Speed (50Hz)
47 CFM[4]
Accurate?
Ultimate Vacuum (60Hz)
7.5 x 10-3 Torr[3]
Accurate?
Ultimate Pressure (50Hz)
2.3 x 10-2 Torr[4]
Accurate?
Maximum Continuous Inlet Pressure
1x10*5 Pa[2]
Accurate?
Exhaust Connection
KF40[3]
Accurate?
Warm-up Time to Nominal Pumping Performnce
15 min[4]
Accurate?
Type
Dry Pump[5]
Accurate?
Type
Dry Vacuum Pump[2]
Accurate?
Typical peak pumping speed
96 m3/h at 60Hz[2]
Accurate?
Typical peak pumping speed
80 m3/h[1]
Accurate?
Ultimate vacuum
3 x 10-2 mbar[1]
Accurate?
Pump stages
Four-stage[1]
Accurate?
Pump mechanism
Positive displacement dry pump with intermeshing rotors on common shafts held in phase by timing gears[1]
Accurate?
Cooling
Indirect cooling system; pump motor is water cooled[1]
Accurate?
Gas module
Gas Module introduces purge gas into the iQDP pump[1]
Accurate?
Control options
Pump Display Module, Interface Module, or iQSingle Pumpset Monitor[1]
Accurate?
Cooling motor note
Both the iQDP and QMB pumps have enclosed, water-cooled motors[1]
Accurate?
Equipment type
Dry vacuum pump[5]
Accurate?
Typical peak pumping speed
80 m3/h-1[1]
Accurate?
Type
Dry semiconductor vacuum pump[1]
Accurate?

Dimensions & facilities2

Weight (lbs)
477 lbs[3]
Accurate?
Weight (kg)
216 Kg[4]
Accurate?

Configuration & options6

Inlet Connection
ISO 63[3]2 sources
Accurate?
Outlet Connection
NW 40[2]
Accurate?
Noise Level at 1 m
< 70 dB(A)[4]
Accurate?
Model
IQDP 80[5]
Accurate?
Make
Edwards[5]
Accurate?
Displacement
310 m3h-1[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
IQDP 80 / A53280905———ajvs.com[1]
IQDP 80 / AS3280905———ajvs.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Typical Peak Pumping Speed (60Hz)96 m3/h-1[2]
  • Pumping Speed (60Hz)56.5 CFM[3]
  • Pumping Speed (50Hz)47 CFM[4]
  • Ultimate Vacuum (60Hz)7.5 x 10-3 Torr[3]
  • Ultimate Pressure (50Hz)2.3 x 10-2 Torr[4]
  • Maximum Continuous Inlet Pressure1x10*5 Pa[2]
  • Exhaust ConnectionKF40[3]
  • Motor3 Phase, 200-460V, 50/60Hz[3]
  • Warm-up Time to Nominal Pumping Performnce15 min[4]
  • TypeDry Pump[5]
  • TypeDry Vacuum Pump[2]
  • Typical peak pumping speed96 m3/h at 60Hz[2]
  • Typical peak pumping speed80 m3/h[1]
  • Ultimate vacuum3 x 10-2 mbar[1]
  • Pump stagesFour-stage[1]
  • Pump mechanismPositive displacement dry pump with intermeshing rotors on common shafts held in phase by timing gears[1]
  • CoolingIndirect cooling system; pump motor is water cooled[1]
  • Gas moduleGas Module introduces purge gas into the iQDP pump[1]
  • Control optionsPump Display Module, Interface Module, or iQSingle Pumpset Monitor[1]
  • Cooling motor noteBoth the iQDP and QMB pumps have enclosed, water-cooled motors[1]
  • Equipment typeDry vacuum pump[5]
  • Typical peak pumping speed80 m3/h-1[1]
  • TypeDry semiconductor vacuum pump[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the ultimate vacuum of the iQDP 80?

The ultimate vacuum is 3 x 10^-2 mbar.[1]

What inlet connection does the iQDP 80 use?

The inlet connection is ISO 63.[2][1]

Does the iQDP 80 use oil in the pumping chamber?

No, the pumping chamber has no lubricating or sealing fluid, ensuring a clean vacuum without oil back-migration.[2][1]

What optional accessories allow control of the iQ system?

The pump can be controlled via an optional Pump Display Module, an Interface Module, or an iQSingle Pumpset Monitor accessory.[1]

Not publicly documented

The following facts about the IQDP 80 Dry are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the IQDP 80 Dry are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the IQDP 80 Dry are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the IQDP 80 Dry are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the IQDP 80 Dry is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the IQDP 80 Dry are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]ajvs.com — ajvs.comajvs.com
  2. [2]ajvs.com — ajvs.comajvs.com
  3. [3]provac.comprovac.com
  4. [4]ecjent.comecjent.com
  5. [5]Equipment inventory listing
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →