Canon MPA 600 FA Projection is a lithography projection aligner. Canon MPA 600 FA Projection is a 1X mirror projection mask aligner. Canon MPA 600 FA Projection supports wafer sizes of 4", 5", and 6".[1][2]

MPA 600 FA Projection — Inventory photo
Fig. 01MPA 600 FA ProjectionInventory photo[3]

Power

2 kW high pressure mercury lamp[1]

Performance

Spot Beam / Sheet Beam[1]

Gas delivery

1.5 um (using positive resist)[1]

Optics

1X Mirror Projection Mask Aligner[1]

What it is

The Canon MPA 600 FA is a 1X mirror projection auto feeder system with backside wafer handling.[1][2]

How it works

The Canon MPA 600 FA uses automatic alignment with a HeNe laser beam scanning system at 633 nm, and it supports spot beam and sheet beam alignment modes.[1][2]

The Canon MPA 600 FA uses a 2 kW high pressure mercury lamp with i-line, h-line, and g-line wavelengths.[1][2]

Where it fits in the process flow

The Canon MPA 600 FA supports cassette-to-cassette operation and backside wafer handling, which places it in a production alignment and exposure flow rather than a manual contact-only workflow.[1][2]

The Canon MPA 600 FA is specified for wafer sizes of 4 inch, 5 inch, and 6 inch and mask sizes of 5 inch, 6 inch, and 7 inch.[1][2]

Applications

The Canon MPA 600 FA is specified with a 1.5 um resolution using positive resist and an accuracy of 3sigma <= .54 um.[1][2]

What do the numbers mean?

Power & electrical2

Illumination
2 kW high pressure mercury lamp[1]
Accurate?
Intensity
(@ 1800 watts power output) 4" wafer - more than 700 mW, 5" wafer - more than 650 mW, 6" wafer - more than 600 mW[1]
Accurate?

Wafer handling2

Auto Feeder
Single or double, cassette to cassette, backside wafer handling[1]
Accurate?
Wafer Sizes
4", 5", 6"[1]
Accurate?

Gas & chemistry1

Resolution
1.5 um (using positive resist)[1]
Accurate?

Optics & imaging5

Type
1X Mirror Projection Mask Aligner[1]
Accurate?
Mask Sizes
5", 6", 7"[1]
Accurate?
Wavelengths used
365 nm (i-line), 405 nm (h-line), 436 nm (g-line)[1]
Accurate?
Intensity / Exposure Uniformity
within +-3%[1]
Accurate?
Automatic Alignment
HeNe (633 nm) laser beam scanning[1]
Accurate?

Performance2

Alignment Modes
Spot Beam / Sheet Beam[1]
Accurate?
Accuracy
3 sigma <= .54 um[1]
Accurate?

Control & software2

Constant Temperature Control (CTC)
Monitors and controls system temperature within +-.3 degrees C.[1]
Accurate?
PDC
Matic Distortion Control provides fine distortion compensation[1]
Accurate?

Configuration & options1

Type
Projection Aligner[3]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Resolution1.5 um (using positive resist)[1]
  • Illumination2 kW high pressure mercury lamp[1]
  • Intensity(@ 1800 watts power output) 4" wafer - more than 700 mW, 5" wafer - more than 650 mW, 6" wafer - more than 600 mW[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer sizes does the Canon MPA 600 FA support?

The Canon MPA 600 FA is specified for 4 inch, 5 inch, and 6 inch wafers.[1][2]

What exposure light source does the Canon MPA 600 FA use?

The Canon MPA 600 FA uses a 2 kW high pressure mercury lamp.[1][2]

What wavelengths are used by the Canon MPA 600 FA?

The Canon MPA 600 FA uses 365 nm i-line, 405 nm h-line, and 436 nm g-line illumination.[1][2]

What alignment method is specified for the Canon MPA 600 FA?

The Canon MPA 600 FA uses automatic alignment with a HeNe 633 nm laser beam scanning system and spot beam or sheet beam alignment modes.[1][2]

Not publicly documented

The following facts about the MPA 600 FA Projection are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the MPA 600 FA Projection are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the MPA 600 FA Projection are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the MPA 600 FA Projection are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the MPA 600 FA Projection are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the MPA 600 FA Projection is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]servtechinc.com — servtechinc.comservtechinc.com
  2. [2]Canon MPA 600FA - Mirror Projection Aligner | SemiStar — semistarcorp.comsemistarcorp.com
  3. [3]Inventory photo
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →