Waferpedia

Agilent

E 4402 B Spectrum Analyzer

Agilent E 4402 B Spectrum Analyzer family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

AgilentE 4402 B Spectrum Analyzer
No photo available yet

Power

9 kHz to 3 GHz[1]

Performance

±0.4 dB[1]

Optics

640 x 480[1]

What it is

The Agilent E 4402 B is a spectrum analyzer.[2][3]

The E4402B belongs to the ESA series of spectrum analyzers.[3]

The E4402B has a frequency range of 9 kHz to 3.0 GHz.[3]

How it works

The ESA family supports frequency, amplitude, sweep, trigger, bandwidth, and input-path settings that shape how the analyzer acquires and displays a trace.[1][3]

Applications

The ESA family is used for general spectrum analysis tasks and for communications test configurations.[1]

The E4402B supports measurements that include frequency specifications, amplitude specifications, sweep time and trigger behavior, resolution bandwidths, and phase-noise-related performance data.[1]

What do the numbers mean?

Power & electrical9

Frequency Range
9 kHz to 3 GHz[1]
Accurate?
Phase Noise (10 kHz offset)
-101 dBc/Hz (typical)[1]
Accurate?
Phase Noise (100 kHz offset)
-122 dBc/Hz (typical)[1]
Accurate?
Phase Noise (1 MHz offset)
-136 dBc/Hz (typical)[1]
Accurate?
DANL (10 MHz to 1 GHz)
-152 dBm (typical)[1]
Accurate?
Frequency range
9 kHz to 3.0 GHz[1]
Accurate?
Phase noise (10 kHz offset)
-101 dBc/Hz[1]
Accurate?
Phase noise (100 kHz offset)
-122 dBc/Hz[1]
Accurate?
Phase noise (1 MHz offset)
-136 dBc/Hz[1]
Accurate?

Optics & imaging1

Display resolution
640 x 480[1]
Accurate?

Performance1

Amplitude Accuracy
±0.4 dB[1]
Accurate?

Dimensions & facilities2

Weight
15.5 kg (34.2 lbs)[1]
Accurate?
Dimensions (W x H x D)
416 mm x 222 mm x 409 mm[1]
Accurate?

Configuration & options8

Input Attenuator Range
0 to 75 dB, 5 dB steps[1]
Accurate?
Maximum Safe Input (CW)
+30 dBm[1]
Accurate?
Operating Temperature
0 °C to +55 °C[1]
Accurate?
Power Consumption
<300 W[1]
Accurate?
Warm up time
5 minutes[1]
Accurate?
Third order intermodulation distortion
+16 dBm typical[1]
Accurate?
Sensitivity
-166 dBm[1]
Accurate?
Operating temperature range
0 °C to +55 °C[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Frequency Range9 kHz to 3 GHz[1]
  • Phase Noise (10 kHz offset)-101 dBc/Hz (typical)[1]
  • Phase Noise (100 kHz offset)-122 dBc/Hz (typical)[1]
  • Phase Noise (1 MHz offset)-136 dBc/Hz (typical)[1]
  • DANL (10 MHz to 1 GHz)-152 dBm (typical)[1]
  • Frequency range9 kHz to 3.0 GHz[1]
  • Phase noise (10 kHz offset)-101 dBc/Hz[1]
  • Phase noise (100 kHz offset)-122 dBc/Hz[1]
  • Phase noise (1 MHz offset)-136 dBc/Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What frequency range does the Agilent E 4402 B cover?

The E 4402 B covers 9 kHz to 3.0 GHz.[3]

What is the warm-up time specified for the ESA family of spectrum analyzers, which includes the E 4402 B?

The warm-up time is 5 minutes.[1]

What is the typical sensitivity (displayed average noise level) for the ESA family?

The typical sensitivity is -166 dBm.[1]

What is the typical amplitude accuracy of the ESA family?

The typical amplitude accuracy is ± 0.4 dB.[1]

What is the typical third-order intermodulation distortion (TOI) for the ESA family?

The typical third-order intermodulation distortion is +16 dBm.[1]

Not publicly documented

The following facts about the E 4402 B Spectrum Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the E 4402 B Spectrum Analyzer are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the E 4402 B Spectrum Analyzer are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the E 4402 B Spectrum Analyzer are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the E 4402 B Spectrum Analyzer are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the E 4402 B Spectrum Analyzer is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]testworld.com — testworld.comtestworld.com
  2. [2]Equipment inventory listing
  3. [3]https://www.maximinstruments.com/pdf_files/AGILENT_E4402B_User's%20Manual.pdf — maximinstruments.commaximinstruments.com
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →