Waferpedia

Comparison ledger

0021 20868 Partversus34465 A

Applied Materials 0021 20868 Part, Keysight 34465 A, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
0021 20868 PartApplied Materials
34465 AKeysight
OEMApplied MaterialsKeysight
CategoryLab & Support EquipmentLab & Support Equipment
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0021 20868 PartKeysight 34465 A
Cited variants—
  • 34460ATruevolt Series[1]
  • 34461ATruevolt Series[1]
  • 34470ATruevolt Series[1]
Specifications
ConfigurationBar, Bus, Gnd, Turbo Cb Encl, Gen Rack,[2]—
Digits of resolution—6½[1]
Basic DC voltage accuracy (1 year, TCAL ±5°C)—0.0030% of reading + 0.0004% of range (10 V range)[1]
Max reading rate (standard digitizing)—5,000 readings/s[1]
Max reading rate (optional digitizing)—50,000 readings/s[1]
Memory (standard)—50,000 readings[1]
Memory (optional)—2 million readings[1]
DC voltage ranges—100 mV to 1000 V[1]
AC voltage ranges (RMS)—100 mV to 750 V[1]
DC current ranges—1 μA to 10 A[1]
AC current ranges (RMS)—100 μA to 10 A[1]
2- and 4-wire resistance ranges—100 Ω to 1000 MΩ[1]
Capacitance ranges—1.0 nF to 100.0 μF[1]
Frequency range—3 Hz to 300 kHz[1]
Temperature measurement—RTD/PT100, thermistor, thermocouples (K,J,T,E,N,R)[1]
Display—Color graphical, 4.3-inch, dual line display[1]
Interface - USB—Yes[1]
Interface - LAN/LXI Core—Optional[1]
Interface - GPIB—Optional[1]
Basic DCV accuracy—30 ppm[1]
Max reading rate (standard)—5,000 rdgs/s[1]
Max reading rate (with DIG option)—50,000 rdgs/s[1]
Volatile reading memory (standard)—50,000 rdgs[1]
Volatile reading memory (with MEM option)—2,000,000 rdgs[1]
AC voltage ranges—100 mV to 750 V[1]
AC current ranges—100 μA to 10 A[1]
Resistance ranges—100 Ω to 1,000 MΩ[1]
Temperature measurement types—RTD/PT100, thermistor, thermocouples[1]
Weight (34461/65/70A)—3.76 kg (8.3 lb)[1]
Bench dimensions (W x H x D)—261.2 mm x 103.8 mm x 303.2 mm[1]
Standard interfaces—USB, LAN/LXI core, optional GPIB[1]
Series—Truevolt[3]
DC Voltage Accuracy (1 year, 10 V range)—0.0030% of reading + 0.0004% of range[1]
Maximum Reading Rate (DC, standard)—5,000 readings/s[1]
Maximum Reading Rate (DC, with option)—50,000 readings/s[1]
Memory (with option)—2 million readings[1]
Measurement Functions—DCV, ACV, DCI, ACI, 2-wire/4-wire resistance, capacitance, frequency, period, temperature (RTD, thermistor, thermocouple), diode, continuity[1]
Basic DCV Accuracy (1 year, 10 V range)—30 ppm[1]
Rear Panel I/O Interfaces (standard)—LAN/LXI, USB, external trigger[1]
Max reading rate—5,000 rdgs/s (standard), 50,000 rdgs/s optional[1]
Memory—50,000 readings standard, 2 million optional[1]
Weight—3.76 kg (8.3 lb)[1]
Interfaces—LAN/LXI, USB, optional GPIB[1]
Autocalibration—ACAL capable[1]

Plan your fab

Building a Lab & Support Equipment process? Get a complete equipment list.

Open the fab equipment planner →
Sources (3)Every fact above is drawn from these public sources
  1. [1]cdn1.npcdn.netcdn1.npcdn.net
  2. [2]inventory listing
  3. [3]manualslib.commanualslib.com