Attribute
0020 18698 PartApplied Materials
Plasmalab 100Oxford Instruments
OEMApplied MaterialsOxford Instruments
CategoryDepositionDeposition
Wafer size—φ2’, φ4’, φ6’, φ8’ single wafer auto transfer
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0020 18698 PartOxford Instruments Plasmalab 100
Cited variants—
  • System 100 PECVD / FlexAL ALD (thermal/plasma) cluster system[1]
  • Plasmalab 100 PECVD[2]
  • Plasmalab 100 ICP Dielectric Etcher[3]
  • Plasmalab 100 ICP (Compound III-V)[4]
Specifications
ConfigurationDial Cover, Side Local Match, Hdpcvd, Ul[5]Gas Box:[2]
Dry pump—Edwards QDP 40[2]
System Control—HP PC System, Windows XP[2]
Voltage—208 VAC, 3 Phase[2]
Full Load—25 A[2]
Gas 1—MKS 1479 A, 5% SiH4 / N2, 1000 SCCM[2]
Gas 2—MKS 1479 A, NH3, 100 SCCM[2]
Gas 3—MKS 1179 A, N2, 2000 SCCM[2]
Gas 4—MKS 1179 A, N2O, 3000 SCCM[2]
Gas 5—MKS 1179 A, ,O2, 300 SCCM[2]
Gas 6—MKS 1179 A, Ar, 500 SCCM (TEOS carrier gas)[2]
TEOS Thermotank—Thermocenter salvis lab[2]
Chuck—φ202 mm( φ2’, φ4’, φ6’, φ8’)[2]
Shower head—φ225 mm[2]
RF Generator—AE RFX 600 A[2]
Match Box—OPT AMU Oxford[2]
LF Generator—AE LF-5[2]
Valve—VAT 12036-PA 4[2]
MKS valve control—253 B[2]
Wafer size—φ2’, φ4’, φ6’, φ8’ single wafer auto transfer[2]
Chuck diameter—202 mm[2]
Shower head diameter—225 mm[2]
Turbo pump—Alcatel ATP 80/100[2]
System control—HP PC, Windows XP[2]
Full load current—25 A[2]
Commissioned PECVD films—Ammonia free silicon nitride (SiH4-N2), Low stress silicon nitride (SiH4-NH3), Silicon dioxide (SiH4-N2O), Silicon oxynitride (SiH4-N2O-NH3), Amorphous silicon a-Si:N:H[1]
Process type—PECVD (Plasma-Enhanced Chemical Vapor Deposition)[2]
Deposition description—Deposition of various thin films via ALD and PECVD[1]
Wafer handling—φ2', φ4', φ6', φ8' single wafer auto transfer[2]
Load lock—single automated wafer transfer load lock[3]
Chamber configuration—one ICP process module connected to a single automated wafer transfer load lock[3]
Configured use—silicon-based dielectric etching[3]

Plan your fab

Building a Deposition process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]uwaterloo.cauwaterloo.ca
  2. [2]Equipment inventory listing
  3. [3]cnfusers.cornell.educnfusers.cornell.edu
  4. [4]nanolab.berkeley.edunanolab.berkeley.edu
  5. [5]inventory listing