-407B-2-S-CE-S293 RobotversusEXL 200 Integrated Chemistry

ABM -407B-2-S-CE-S293 Robot, Siemens EXL 200 Integrated Chemistry, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMSiemens
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotSiemens EXL 200 Integrated Chemistry
Specifications
ModelABM-407B-2-S-CE-S293[1]—
DescriptionROBOT[1]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[1]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[1]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[1]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[1]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[1]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[1]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[1]—
Throughput—Up to 624 tests/hour: 437 photometric, 187 ISE, 167 immunoassay[2]
Onboard Assays—47 including 3 ISE[2]
Sample Capacity—60 samples in six 10-position segments[3]
Footprint—1.5 sq m (16.2 sq ft)[3]
Weight—770 lbs (349 kg)[2]
Dimensions (without monitor)—56" W x 49" H x 41" D[2]
Power Consumption—1265 W[2]
Operating Temperature Range—64°F – 86°F (18°C – 30°C)[2]
Average Heat Output—3,753 BTU/hr[2]
Reaction Cuvettes—12,000 cuvettes formed onboard[2]
Light Source—Standard tungsten halogen lamp, operation at 6.5A (6.8v)[2]
Assay Methods—Endpoint, rate, multipoint, homogeneous immunoassay, turbidometric, LOCI[2]
Reaction Times—3, 4, 5, 10, 15, and 21 minutes[2]
Onboard Stability—Up to 30 days[2]
Operating System—Linux, 1 GB RAM, 17-inch touch screen monitor[2]
Host Interface—RS-232C bidirectional[2]
Drain Requirement—Maximum 10.6 gallons (40 liters) per hour[2]
Water Feed Requirement—Instrument feed water between 5 and 8 ppm[2]
Calibration Interval—Up to 90 days[2]
Sources (3)Every fact above is drawn from these public sources
  1. [1]dealer listingsemistarcorp.com
  2. [2]mplusmedtech.commplusmedtech.com
  3. [3]siemens-healthineers.comsiemens-healthineers.com