-407B-2-S-CE-S293 Robotversus1100 Series HPLC

ABM -407B-2-S-CE-S293 Robot, Agilent 1100 Series HPLC, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMAgilent
Category——
Wafer size——
Process node——
Introduced——
Production run—1995–
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-2-S-CE-S293 RobotAgilent 1100 Series HPLC
Cited variants—
  • Isocratic Pump G1310A[1]
  • Binary Pump G1312A[2]
  • Quaternary Pump G1311A[1]
  • Capillary Pump[1]
  • Preparative Pump[1]
  • Standard Autosampler G1329A[2]
  • Well-Plate Autosampler (WPALS) G1367A[1]
  • Diode Array Detector G1315B[2]
  • Variable Wavelength Detector G1314A[3]
  • Fluorescence Detector G1321A[1]
  • Refractive Index Detector G1362A[1]
  • Binary VWD System[4]
  • Binary DAD System[4]
  • Quaternary VWD System[4]
  • Quaternary DAD System[4]
Specifications
ModelABM-407B-2-S-CE-S293[5]1100 Series[6]
DescriptionROBOT[5]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[5]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[5]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[5]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[5]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[5]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[5]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[5]—
Flow range (isocratic pump)—0.2 ml/min to 10 ml/min[1]
Flow range (binary pump)—0.1 – 5.0 ml/min (settable 0.001 – 5 ml/min)[2]
Pressure range (binary pump)—0 – 400 bar (0 – 5880 psi)[2]
Flow precision (binary pump)—< 0.3 % RSD (typically 0.15 %) at 1 ml/min[2]
Wavelength range (DAD)—190 – 950 nm[2]
Detector short term noise (DAD)—± 1 × 10⁻⁵ AU at 254 and 750 nm[2]
Autosampler injection range—0.1 – 100 µl (standard), up to 1500 µl with multiple draw[2]
Autosampler precision—Typically < 0.5 % RSD from 5 – 100 µl[2]
Module weight (isocratic pump, VWD, TCC)—11.0 kg (25.0 lbs) each[3]
Module dimensions (width × depth × height, most modules)—345 × 435 × 140 mm (13.5 × 17 × 5.5 in)[3]
Line voltage—100 – 120 or 220 – 240 VAC, ± 10 %[3]
Ambient operating temperature—0 – 55 °C (32 – 131 °F)[3]
Make/OEM—Agilent (formerly Hewlett-Packard)[6]
Category—High Performance Liquid Chromatography (HPLC)[6]
Introduction Year—1995[2]
Modules/Components—Isocratic pump (G1310A), binary pump (G1312A), quaternary pump (G1311A), capillary pump, preparative pump, standard autosampler (G1313A), well-plate autosampler, thermostatted micro autosampler, micro well-plate autosampler, thermostatted column compartment (G1316A), vacuum degasser (G1322A), variable wavelength detector (G1314A/B), diode array detector (G1315A/B), multiwavelength detector, fluorescence detector (G1321A), refractive index detector (G1362A), mass selective detector LC/MSD VL/SL, LC/MSD Trap, controllers, handheld control module, ChemStation software[1]
Pump Flow Range (Isocratic)—0.001 – 10 ml/min[1]
Pump Flow Range (Binary)—0.001 – 5.0 ml/min[1]
Pump Flow Range (Quaternary)—0.001 – 10 ml/min[1]
Pump Flow Range (Capillary)—0.01 μl/min – 2.5 ml/min[1]
Pump Flow Range (Preparative)—0.001 – 100 ml/min[1]
Flow Precision—0.3% RSD (typically < 0.15% RSD)[1]
Pressure Range (Binary/Isocratic/Quaternary)—0 – 400 bar (0 – 5880 psi)[2]
VWD Wavelength Range—190 – 600 nm[1]
DAD/MWD Wavelength Range—190 – 950 nm[1]
DAD Short-term Noise—± 1 × 10-5 AU at 254 nm and 750 nm[1]
Column Compartment Temperature Range—10 °C below ambient to 80 °C[1]
Autosampler Injection Volume (Standard)—0.1 – 100 μl standard range, up to 1800 μl or 5000 μl with extension[1]
Detectors—Variable Wavelength (VWD), Multiwavelength (MWD), Diode Array (DAD), Fluorescence (FLD), Refractive Index (RID), Mass Selective (LC/MSD VL/SL, LC/MSD Trap)[1]
Control and Data Handling—Handheld controller, Agilent ChemStation (2D/3D), Cerity Networked Data System, ChemStation Plus, Security Pack for 21 CFR Part 11 compliance[1]
Communications—Controller-area network (CAN), GPIB, RS-232C, APG Remote (ready, start, stop, shut-down), LAN (optional)[2]
Dimensions (Isocratic Pump, VWD, FLD)—345 mm × 435 mm × 140 mm (13.5 × 17 × 5.5 inches) (W × D × H)[3]
Weight (Isocratic Pump)—11.0 kg (25.0 lbs)[3]