Comparison ledger
Keysight 34465 A, Tri -Mist 850 Electronic Air Filter, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | 34465 AKeysight | |
|---|---|---|
| OEM | Keysight | Tri |
| Category | Lab & Support Equipment | Lab & Support Equipment |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | Keysight 34465 A | Tri -Mist 850 Electronic Air Filter |
| Cited variants | — | |
| Specifications | ||
| Digits of resolution | 6½[1] | — |
| Basic DC voltage accuracy (1 year, TCAL ±5°C) | 0.0030% of reading + 0.0004% of range (10 V range)[1] | — |
| Max reading rate (standard digitizing) | 5,000 readings/s[1] | — |
| Max reading rate (optional digitizing) | 50,000 readings/s[1] | — |
| Memory (standard) | 50,000 readings[1] | — |
| Memory (optional) | 2 million readings[1] | — |
| DC voltage ranges | 100 mV to 1000 V[1] | — |
| AC voltage ranges (RMS) | 100 mV to 750 V[1] | — |
| DC current ranges | 1 μA to 10 A[1] | — |
| AC current ranges (RMS) | 100 μA to 10 A[1] | — |
| 2- and 4-wire resistance ranges | 100 Ω to 1000 MΩ[1] | — |
| Capacitance ranges | 1.0 nF to 100.0 μF[1] | — |
| Frequency range | 3 Hz to 300 kHz[1] | — |
| Temperature measurement | RTD/PT100, thermistor, thermocouples (K,J,T,E,N,R)[1] | — |
| Display | Color graphical, 4.3-inch, dual line display[1] | — |
| Interface - USB | Yes[1] | — |
| Interface - LAN/LXI Core | Optional[1] | — |
| Interface - GPIB | Optional[1] | — |
| Basic DCV accuracy | 30 ppm[1] | — |
| Max reading rate (standard) | 5,000 rdgs/s[1] | — |
| Max reading rate (with DIG option) | 50,000 rdgs/s[1] | — |
| Volatile reading memory (standard) | 50,000 rdgs[1] | — |
| Volatile reading memory (with MEM option) | 2,000,000 rdgs[1] | — |
| AC voltage ranges | 100 mV to 750 V[1] | — |
| AC current ranges | 100 μA to 10 A[1] | — |
| Resistance ranges | 100 Ω to 1,000 MΩ[1] | — |
| Temperature measurement types | RTD/PT100, thermistor, thermocouples[1] | — |
| Weight (34461/65/70A) | 3.76 kg (8.3 lb)[1] | — |
| Bench dimensions (W x H x D) | 261.2 mm x 103.8 mm x 303.2 mm[1] | — |
| Standard interfaces | USB, LAN/LXI core, optional GPIB[1] | — |
| Series | Truevolt[2] | — |
| DC Voltage Accuracy (1 year, 10 V range) | 0.0030% of reading + 0.0004% of range[1] | — |
| Maximum Reading Rate (DC, standard) | 5,000 readings/s[1] | — |
| Maximum Reading Rate (DC, with option) | 50,000 readings/s[1] | — |
| Memory (with option) | 2 million readings[1] | — |
| Measurement Functions | DCV, ACV, DCI, ACI, 2-wire/4-wire resistance, capacitance, frequency, period, temperature (RTD, thermistor, thermocouple), diode, continuity[1] | — |
| Basic DCV Accuracy (1 year, 10 V range) | 30 ppm[1] | — |
| Rear Panel I/O Interfaces (standard) | LAN/LXI, USB, external trigger[1] | — |
| Max reading rate | 5,000 rdgs/s (standard), 50,000 rdgs/s optional[1] | — |
| Memory | 50,000 readings standard, 2 million optional[1] | — |
| Weight | 3.76 kg (8.3 lb)[1] | — |
| Interfaces | LAN/LXI, USB, optional GPIB[1] | — |
| Autocalibration | ACAL capable[1] | — |
Plan your fab