6890 Gas Chromatographyversus6890 GCversus6890 GC-MS

Agilent 6890 Gas Chromatography, Agilent 6890 GC, Agilent 6890 GC-MS, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
6890 GCAgilent
6890 GC-MSAgilent
OEMAgilentAgilentAgilent
CategoryThermal / Diffusion—Precision Optics
Wafer size———
Process node———
Introduced———
Production run———
Lifecycle———
Lifecycle milestones———
Control system———
Generation———
FamilyAgilent 6890Agilent 6890Agilent 6890
Cited variants——
Specifications
ConfigurationIncludes:[2]With[4]With 5973 MSD[5]
InjectorSplit-splitless (standard), others available[2]——
Oven temperatureAmbient +4 - 450 'C[2]——
Oven ramps / plateaus6-7[2]——
Carrier gasesHelium, hydrogen, nitrogen, argon[2]——
Electronic pnuematic controlAuto pressure regulation for split/splitless, septum purge[2]——
Carrier gas control modesConstant pressure and flow modes; pressure and flow programmable[2]——
Pressure range0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected[2]——
Retention-time lockingRTL ready[2]——
Flow controlCompatible with optional microfluidics controller[2]——
MakeAgilent[2]——
Model6890[2]——
Electronic pneumatic controlAuto pressure regulation for split/splitless, septum purge[2]——
Mainframes6890A, 6890A Plus, and 6890N[1]——
Communication6890A uses HPIB (GPIB); 6890A Plus uses HPIB and can be upgraded to LAN; 6890N comes standard with LAN[1]——
EPC architecture13-channel digital EPC[3]——
Pressure accuracy±0.01 psi[3]——
Temperature stability±0.01 °C[3]——
Oven range–60 to 450 °C[3]——
Oven ramp rateUp to 120 °C/min[3]——
Data acquisition rateUp to 100 Hz[3]——
Retention time lockingEnabled for cross-instrument method transfer[3]——
InjectorsSplit-splitless (standard), others available[2]——
Detector optionsFID, uECD, TCD, PID, FPD, NPD, PDD, MSD, Triple Quadrupole TQ Mass Spec[1]——
Injection portsSplit/Splitless Inlet, Cool On-Column Inlet, Purged Packed Inlet, PTV Inlet, Volatiles Interface[1]——
OriginUSA[3]——
Operational age5–7 years[3]——
Warranty6 months[3]——
Regulatory complianceDesigned for GLP/GMP environments with audit-trail-capable data handling[3]——
Software platformOpenLAB CDS ChemStation (legacy-compatible)[3]——
EPC control13-channel digital electronic pressure control (EPC), pressure accuracy ±0.01 psi[3]——
Temperature programOven ramp rate up to 120 C/min, temperature stability ±0.01 C[3]——
Retention Time Locking (RTL)Enabled for cross-instrument method transfer[3]——

Plan your fab

Building a Thermal / Diffusion process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]aimanalytical.comaimanalytical.com
  2. [2]inventory listing
  3. [3]instrumenthive.cominstrumenthive.com
  4. [4]inventory listing
  5. [5]inventory listing