Comparison ledger
ABM -407B-2-S-CE-S293 Robot, ESPEC TSE 12 A Thermal Shock, side by side. Every value shown is drawn from the cited encyclopedia entries.
| Attribute | ||
|---|---|---|
| OEM | ABM | ESPEC |
| Category | — | — |
| Wafer size | — | — |
| Process node | — | — |
| Introduced | — | — |
| Production run | — | — |
| Lifecycle | — | — |
| Lifecycle milestones | — | — |
| Control system | — | — |
| Generation | — | — |
| Family | ABM -407B-2-S-CE-S293 Robot | ESPEC TSE 12 A Thermal Shock |
| Specifications | ||
| Model | ABM-407B-2-S-CE-S293[1] | — |
| Description | ROBOT[1] | — |
| Refurbished RTP RTA | AG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[1] | — |
| KLA-Tencor Spare Parts and Service | RS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[1] | — |
| Refurbished Isotropic Plasma Etcher | Matrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[1] | — |
| Refurbished PECVD, ALD Equipment | Cambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[1] | — |
| Refurbished Mask Aligner | Canon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[1] | — |
| Refurbished Bonding | SUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[1] | — |
| Refurbished Wafer Prober | Electroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[1] | — |
| Phase | — | 3 Phase[2] |
| Frequency | — | 60 Hz[2] |
| Interior Volume | — | 0.4 cu. ft. (11 Liters)[3] |
| Interior Dimensions (W x D x H) | — | 12.5" x 9.1" x 5.8" (320 x 230 x 150 mm)[3] |
| Exterior Dimensions (W x D x H) | — | 26" x 42" x 79" (NEC compliant version) (680 x 1050 x 2007 mm)[3] |
| Temperature Range | — | -65 to 200°C (-85 to 392°F)[3] |
| Power | — | 208V (±5%) 3ph 60Hz 30 Service Amps (26 FLA)[3] |
| Maximum Sound Level (1 meter away) | — | 60 dBA[3] |
| Temperature Fluctuation (at control sensor) | — | ±0.5°C[3] |
| Refrigeration System | — | Cascade 2hp Scroll[3] |
| Transfer Mechanism | — | Vertical-lift, direct-drive system for reliable transfer between zones[4] |
| Maximum Load | — | 17 lb. (4 kg)[4] |
| Specimen Baskets | — | Two specimen baskets[4] |
| Cable Port | — | Tube for cables to test load, 2" diameter[4] |
| Specimen Power Supply Terminal | — | Included[4] |
| Refrigeration Type | — | Non-CFC cascade refrigeration system using 2-hp compressors[4] |
| Air Circulation | — | Two sirocco blower motors circulate the air (one per zone)[4] |
| Controller | — | ESPEC's Exclusive P-310 Programmer with 7" color touch-screen[4] |
| Programs | — | 20 user-definable programs can be saved with alphanumeric names[4] |
| Connectivity | — | Ethernet with browser-based access is standard, plus USB[4] |
| Utility Requirement | — | The only utility required is 208V power[4] |
| Width | — | Only 26 inches wide[4] |
| Compliance | — | Meets Mil-Std 883 1010.7/1010.8 thermal cycling requirements with 4 kg load; also can be used for IEC 61300-2-47, JEDEC JESD47E, JESD22-A104, and others[4] |
| Test Performance Example | — | Test: Mil-Std 883 1010.7 Range: -65 to 150°C Recovery: 15 min. (worst-case on-product) Load: 6 lb of IC chips[3] |
| Test performance example | — | Mil-Std 883 1010.7; range -65 to 150°C; recovery 15 min. (worst-case on-product); load 6 lb of IC chips[3] |
| Heat-to-room peak | — | 17,000 BTU/Hr.[3] |
| Maximum sound level | — | 60 dBA (1 meter away)[3] |
| Temperature fluctuation | — | ±0.5°C at control sensor[3] |
| Maximum load | — | 17 lb.[3] |
| Cable tube diameter | — | 2 in.[3] |
| Display | — | 7 in. color touch-screen[3] |