Waferpedia

Comparison ledger

-407B-1-S-CES293 RobotversusG 1888 Network Headspace Sampler

ABM -407B-1-S-CES293 Robot, Agilent G 1888 Network Headspace Sampler, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMABMAgilent
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyABM -407B-1-S-CES293 RobotAgilent G 1888 Network Headspace Sampler
Specifications
ModelABM-407B-1-S-CES293[1]G1888[2]
DescriptionROBOT[1]—
Refurbished RTP RTAAG Associates 4100, 4108, 8108, 8800, 8800i,210, 310, 410, 610, 610I, MPT RTP-600S, 800S, RTP-3000[1]—
KLA-Tencor Spare Parts and ServiceRS-35C,RS-55,RS-75,RS-100,UV-1050,UV-1080,UV-1250,UV-1280,ASET F5 / F5X,AIT Systems,HRP-220 Stylus Profiler[1]—
Refurbished Isotropic Plasma EtcherMatrix, Tegal, Lam Research, Branson/IPC, PlasmaTherm[1]—
Refurbished PECVD, ALD EquipmentCambridge, Oxford PlasmaLab , Plasma-Therm, STS/SPTS, AMAT[1]—
Refurbished Mask AlignerCanon Neutronix PLA501/545, Suss MA200CC, MA8BA8 GEN3, MA8BA8 GEN2, MA8BA8, MA200E[1]—
Refurbished BondingSUSS SB6E, SUSS SB8E, EVG 620 BA, EVG EV501, West Bond 7200AR 7400A[1]—
Refurbished Wafer ProberElectroglas EG 4090u+, EG 4090, EG 2001X, EG 1034X, Cascade PS-21[1]—
Manufacturer—Agilent Technologies[2]
Sampling method—Static headspace sampling[3]
Technique—Automated headspace sampling for gas chromatography[3]
Injection type—Heated transfer line to GC inlet[3]
Operation—Fully automated vial heating, equilibration, pressurization, and injection[3]
Vial capacity—70-sample tray, 12 oven positions[4]
Oven range—40 to 230°C[4]
Oven temperature range—Ambient to ~200 °C[3]
Sample loop—1 mL standard, 3 mL optional[4]
Transfer line—85 cm[4]
Extraction modes—Single, multi-puncture (to 100), concentration mode[4]
Vial sizes supported—Commonly 10 mL and 20 mL headspace vials[3]
Carrier / pressurization gas—Helium, nitrogen, or other GC-compatible gases[3]
Control—Integrated with Agilent GC electronic pneumatic control (EPC)[3]
Sample pathway—Inert sample pathway with deactivated sample path from needle to transfer line[4]
Network control—Controlled over a network by GC ChemStation, MSD Productivity ChemStation, MSD Security ChemStation, or Cerity NDS[4]
Keypad—Built-in keypad runs the sampler standalone[4]
Event log—Tracks every operation and flags temperature or pressure deviation from setpoint, in line with 21 CFR Part 11[4]
GC compatibility—Agilent GC and GC-MS platforms (commonly 6890/7890 series)[3]
Detectors—FID, MS, ECD (method-dependent)[3]
Headspace Sampler to GC connection—Supports EPC and MPC configurations; EPC using 6850 and 6890 GCs; EPC using 7890 GC; MPC connections[5]
Carrier gas connections—Carrier and pressurization gas supplies; common carrier gas connections; vial pressurization gas connection; headspace sampler vent connection[5]
Sources (5)Every fact above is drawn from these public sources
  1. [1]dealer listingsemistarcorp.com
  2. [2]Equipment inventory listing
  3. [3]alliantscientific.comalliantscientific.com
  4. [4]gentechscientific.comgentechscientific.com
  5. [5]conquerscientific.comconquerscientific.com